CERES
CERES TEST Only!
  • Communities & Collections
  • Browse CERES
  • Library Staff Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Gomes, Maria Adelina"

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Estimating measurement uncertainty in the medical laboratory
    (Cranfield University, 2016-09) Placido, Rui; Newman, Jeffrey D.; Gomes, Maria Adelina
    Medical Laboratories Accreditation is covered by ISO 15189:2012 - Medical Laboratories — Requirements for Quality and Competence. In Portugal, accreditation processes are held under the auspices of the Portuguese Accreditation Institute (IPAC), which applies the Portuguese edition (NP EN ISO 15189:2014). Accordingly, Medical Laboratories accreditation processes now require the estimate of measurement uncertainty (MU) associated to the results. The Guide to the Expression of Uncertainty in Measurement (GUM) describes the calculation of MU, not contemplating the specific aspects of medical laboratory testing. Several models have been advocated, yet without a final consensus. Given the lack of studies on MU in Portugal, especially on its application in the medical laboratory, it is the objective of this thesis to reach to a model that fulfils the IPAC’s accreditation regulations, in regards to this specific requirement. The study was based on the implementation of two formulae (MU-A and MU-B), using the Quality Management System (QMS) data of an ISO 15189 Accredited Laboratory. Including the laboratory’s two Cobas® 6000–c501 (Roche®) analysers (C1 and C2) the work focused three analytes: creatinine, glucose and total cholesterol. The MU-B model formula, combining the standard uncertainties of the method’s imprecision, of the calibrator’s assigned value and from the pre-analytical variation, was considered the one best fitting to the laboratory's objectives and to the study's purposes, representing well the dispersion of values reasonably attributable to the measurand final result. Expanded Uncertainties were: Creatinine - C1 = 9,60%; C2 = 5,80%; Glucose - C1 = 8,32%; C2 = 8,34%; Cholesterol - C1 = 4,00%; C2 = 3,54 %. ...[cont.].

Quick Links

  • About our Libraries
  • Cranfield Research Support
  • Cranfield University

Useful Links

  • Accessibility Statement
  • CERES Takedown Policy

Contacts-TwitterFacebookInstagramBlogs

Cranfield Campus
Cranfield, MK43 0AL
United Kingdom
T: +44 (0) 1234 750111
  • Cranfield University at Shrivenham
  • Shrivenham, SN6 8LA
  • United Kingdom
  • Email us: researchsupport@cranfield.ac.uk for REF Compliance or Open Access queries

Cranfield University copyright © 2002-2025
Cookie settings | Privacy policy | End User Agreement | Send Feedback