CERES
CERES TEST Only!
  • Communities & Collections
  • Browse CERES
  • Library Staff Log In
    New user? Click here to register. Have you forgotten your password?
  1. Home
  2. Browse by Author

Browsing by Author "Khan, M. N."

Now showing 1 - 1 of 1
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    ItemOpen Access
    Comparative ambient and indoor particulate matter analysis of operation theatres of government and private (trust) hospitals of Lahore, Pakistan
    (Pakistan Agricultural Scientists Forum, 2015-06-30) Nimra, A.; Ali, Z.; Khan, M. N.; Gulshan, T.; Sidra, S.; Gardezi, J. R.; Tarar, M. R.; Saleem, M.; Nasir, Zaheer A.; Colbeck, Ian
    The link between infection and indoor air quality (IAQ) in operating theatres is well established. The level of airborne particulate matter (PM) in operating theatres in Pakistan has not yet been studied comprehensively. Monitoring of both indoor (operating theatre) and outdoor concentrations of PM in both activity and non-activity time periods was done using a DUSTTRAK Aerosol Monitor (TSI Model 8520) and DRX Aerosol Monitor (TSI Model 8533) for 24 hours. Two hospitals in Lahore were selected: Services Hospital (government – site 1) and Shalamar Hospital (private – site 2). The highest concentration of PM was observed in the orthopaedic operating theatre at site 1 during working hours with an average concentration of 757(±540), 809(±58), 824(±585), 875(±586) and 970(±581) µg/m³ of PM1 ,PM2.5, PM4, PM10and PMTotalrespectively while the average PM2.5outdoor concentration was 294 µg/m3 . The minimum average PM concentration was found in the orthopaedic operating theatre at site 2 during working hours: 18(±8), 19(±8), 20(±9), 26(±9) and 39(±9) µg/m³ for PM1, PM2.5, PM4, PM10 and PMTotal respectively. The use of vertical laminar air flow ventilation strategy was found to be an effective measure in reducing PM levels and it might be possible to predict the air quality of operating theatres by determining PM dust load. Factors such as ventilation system, door opening /closing rates, building age, possible sources of infiltration, number of people present in the operating area all play a role in influencing PM concentrations in operating theatres.

Quick Links

  • About our Libraries
  • Cranfield Research Support
  • Cranfield University

Useful Links

  • Accessibility Statement
  • CERES Takedown Policy

Contacts-TwitterFacebookInstagramBlogs

Cranfield Campus
Cranfield, MK43 0AL
United Kingdom
T: +44 (0) 1234 750111
  • Cranfield University at Shrivenham
  • Shrivenham, SN6 8LA
  • United Kingdom
  • Email us: researchsupport@cranfield.ac.uk for REF Compliance or Open Access queries

Cranfield University copyright © 2002-2025
Cookie settings | Privacy policy | End User Agreement | Send Feedback