Browsing by Author "Lin, Yaoying"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Open Access Advancing two-phase wet gas flow measurement with Coriolis meters: optimal sensor orientation and a new model development(Elsevier, 2025-03-01) Salehi, Seyed Milad; Lao, Liyun; Simms, Nigel; Drahm, Wolfgang; Lin, Yaoying; Rieder, Alfred; Güttler, AndreasIn this study, a novel wet gas model was developed based on the internal parameter of a Coriolis prototype to measure two-phase wet gas flow. Additionally, an optimal orientation of the Coriolis sensor was proposed to address challenges in the horizontal wet gas flow. Two Coriolis prototypes– one with a long-bent flow tubes (Type A), and another with short-bent flow tubes (Type B) – were employed to conduct tests in both vertical upward and horizontal pipelines. Different sensor axial angles (0, 40, 90, and 180°) were selected for testing in the horizontal section. Among different orientations (angles), it was found that the 40-degree angle outperforms the other installations in terms of the response proximity and over-reading of gas flow (OR). To understanding the impact of flow pattern on the response, a detailed analysis of different flow patterns in the wet gas was considered. A new correlation was developed between the damping factor of the Coriolis and both XLM and the total mass flow rate, leading to the proposal of a new wet gas model to predict gas and liquid flow rates with acceptable accuracy. In scenarios involving higher Froude numbers and annular flow patterns, which are more likely to occur, the Mean Absolute Percentage Error (MAPE) for the entire range of wetness (0 < XLM < 0.3) is 3.9 % for gas flow rate and 4.3 % for liquid flow rate with an uncertainty of 2.7 %.Item Open Access Response of a coriolis gas flow meter to steady and transient wet gas flow conditions(Avestia Publishing, 2024-04-13) Salehi, Seyed Milad; Lao, Liyun; Simms, Nigel; Drahm, Wolfgang; Lin, Yaoying; Rieder, Alfred; Güttler, AndreasCoriolis devices are continuously evolving to meet the demands of different conditions, such as wet gas flow. However, their application in wet gas flow has not yet been thoroughly explored. The impact of steady flow disturbances on Coriolis flow meters is well-documented, and empirical compensation or correction methods can be implemented accordingly. However, there has been inadequate investigation into the response of Coriolis meters under transient flow conditions and their comparison with steady flow in a wet gas. In this study, a Coriolis device was horizontally installed in a 50 mm pipe diameter. The experimental fluids consisted of air and water, with Lockhart-Martinelli (XLM) values ranging from 0.02 to 0.40. Steady and transient flow conditions at different gas and liquid flow rates were studied. The findings demonstrate the capability of standard deviation (STD) in distinguishing transient flow from steady one. Additionally, a strong correlation was observed between XLM and gas Over-Reading (OR) across various gas flow rates and XLM values. This correlation is particularly evident for XLM < 0.1. At extremely low liquid loading (XLM < 0.05), the average percentage error remains below 7 % even without the utilization of any correction models. Furthermore, the impact of different sensor installations, which had been largely overlooked in previous studies, was investigated.