Browsing by Author "Yong, Yang-Chun"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
Item Open Access Review of paper-based microfluidic analytical devices for in-field testing of pathogens(Elsevier, 2023-09-12) Li, Wenliang; Ma, Xuanye; Yong, Yang-Chun; Liu, Guozhen; Yang, ZhugenPathogens cause various infectious diseases and high morbidity and mortality which is a global public health threat. The highly sensitive and specific detection is of significant importance for the effective treatment and intervention to minimise the impact. However, conventional detection methods including culture and molecular method gravely depend on expensive equipment and well-trained skilled personnel, limiting in the laboratory. It remains challenging to adapt in resource-limiting areas, e.g., low and middle-income countries (LMICs). To this end, low-cost, rapid, and sensitive detection tools with the capability of field testing e.g., a portable device for identification and quantification of pathogens, has attracted increasing attentions. Recently, paper-based microfluidic analytical devices (μPADs) have shown a promising tool for rapid and on-site diagnosis, providing a cost-effective and sensitive analytical approach for pathogens detection. The fast turn-round data collection may also contribute to better understanding of the risks and insights on mitigation method. In this paper, critical developments of μPADs for in-field detection of pathogens both for clinical diagnostics and environmental surveillance are reviewed. The future development, and challenges of μPADs for rapid and onsite detection of pathogens are discussed, including using the cross-disciplinary development with, emerging techniques such as deep learning and Internet of Things (IoT).Item Open Access Self-assembled microfiber-like biohydrogel for ultrasensitive whole-cell electrochemical biosensing in microdroplets(American Chemical Society, 2023-01-27) Ma, Xiao-Meng; Wang, Jian-Wei; Zhao, Li-Ting; Zhang, Yafei; Liu, Jun-Ying; Wang, Songmei; Zhu, Daochen; Yang, Zhugen; Yong, Yang-ChunA novel microfiber-like biohydrogel was fabricated by a facile approach relying on electroactive bacteria-induced graphene oxide reduction and confined self-assembly in a capillary tube. The microfiber-like biohydrogel (d = ∼1 mm) embedded high-density living cells and activated efficient electron exchange between cells and the conductive graphene network. Further, a miniature whole-cell electrochemical biosensing system was developed and applied for fumarate detection under −0.6 V (vs Ag/AgCl) applied potential. Taking advantage of its small size, high local cell density, and excellent electron exchange, this microfiber-like biohydrogel-based sensing system reached a linear calibration curve (R2 = 0.999) ranging from 1 nM to 10 mM. The limit of detection obtained was 0.60 nM, which was over 1300 times lower than a traditional biosensor for fumarate detection in 0.2 μL microdroplets. This work opened a new dimension for miniature whole-cell electrochemical sensing system design, which provided the possibility for bioelectrochemical detection in small volumes or three-dimensional local detection at high spatial resolutions.Item Open Access Soil microbial fuel cell based self-powered cathodic biosensor for sensitive detection of heavy metals(MDPI, 2023-01-15) Wang, Shi-Hang; Wang, Jian-Wei; Zhao, Li-Ting; Abbas, Syed Zaghum; Yang, Zhugen; Yong, Yang-ChunSoil microbial fuel cells (SMFCs) are an innovative device for soil-powered biosensors. However, the traditional SMFC sensors relied on anodic biosensing which might be unstable for long-term and continuous monitoring of toxic pollutants. Here, a carbon-felt-based cathodic SMFC biosensor was developed and applied for soil-powered long-term sensing of heavy metal ions. The SMFC-based biosensor generated output voltage about 400 mV with the external load of 1000 Ω. Upon the injection of metal ions, the voltage of the SMFC was increased sharply and quickly reached a stable output within 2~5 min. The metal ions of Cd2+, Zn2+, Pb2+, or Hg2+ ranging from 0.5 to 30 mg/L could be quantified by using this SMFC biosensor. As the anode was immersed in the deep soil, this SMFC-based biosensor was able to monitor efficiently for four months under repeated metal ions detection without significant decrease on the output voltage. This finding demonstrated the clear potential of the cathodic SMFC biosensor, which can be further implemented as a low-cost self-powered biosensor.