CERESResearch Repository

Spine motion segment analogues: 3D printing, multiscale modelling and testing to produce more biofidelic examples

dc.contributor.authorFranceskides, Constantinos
dc.contributor.authorShanker, Tobias
dc.contributor.authorGibson, Michael C.
dc.contributor.authorZioupos, Peter
dc.date.accessioned2026-03-04T12:19:52Z
dc.date.available2026-03-04T12:19:52Z
dc.date.freetoread2026-03-04
dc.date.issued2026-02
dc.date.pubOnline2026-02-06
dc.descriptionThis article belongs to the Special Issue Recent Advances in 3D Printing Technologies in Bioengineering with Selected Papers from the 29th Congress of the European Society of Biomechanics (ESB 2024)
dc.description.abstractComputed tomography and magnetic resonance imaging are two powerful modalities which can be used in the clinical setting to produce data for the creation of patient-specific finite element analysis (FEA) models and physical analogues—for instance, by using additive manufacturing (AM)—that mimic the properties of soft and hard tissues, both morphologically and mechanically. However, there remains a gap between creating a perfect biofidelic physical analogue and its computational counterpart. This gap exists because, firstly, in silico models are often too complex to realise, and secondly, real-life conditions are challenging to emulate both computationally and mechanically, as they involve multiscale situations that are inherently heterogeneous and patient specific. In this study, we applied a multi-scale approach to design and model porcine vertebral specimens. Our results identified critical design factors that affect the quality and accuracy of the models, specifically highlighting that scanning resolution/fidelity and the thresholding technique have a directly proportional impact on model accuracy. A small shift up and down the greyscale level by 20 units can affect the behaviour of the AM sample by as much as [−15% +47%]. Working up the levels for manufacturing, testing and modelling (i) cylindrical cores to (ii) whole vertebrae and then (iii) a whole spine motion segment, we observed that the fidelity of predictions reduces, and errors increase as the structure becomes more complicated and intricate (3.6%, 7.5% and 15%, respectively). We are confident that further material-level developments will provide solutions for the more intricate parts of spinal motion segments, such as the intervertebral discs and facets, which in their natural form are highly sophisticated structures. To the best of our knowledge, this is the first time a holistic multiscale approach has been implemented to produce AM biofidelic analogues of skeletal parts. Our data showed good agreement between the physical and in silico models, confirming that it is possible to model real-time objects and situations both physically and in silico. This ultimately will enable the development of accurate, patient-specific physical models for use in biomechanical testing and medicolegal applications.
dc.description.conferencename29th Congress of the European Society of Biomechanics (ESB 2024)
dc.description.journalNameJournal of Manufacturing and Materials Processing
dc.description.sponsorshipThe authors disclosed receipt of the following financial support for the research, authorship, and/or publication of this article from a CDS Cranfield University internal funding to C.F. and T.S. and funding to P.Z. from RCDM (Royal College for Defence Medicine), Birmingham (grant no.DMSRSG20130905).
dc.identifier.citationFranceskides C, Shanker T, Gibson MC, Zioupos P. (2026) Spine motion segment analogues: 3D printing, multiscale modelling and testing to produce more biofidelic examples. Journal of Manufacturing and Materials Processing, Volume 10, Issue 2, February 2026, Article number 56en_UK
dc.identifier.eissn2504-4494
dc.identifier.elementsID868802
dc.identifier.issn2504-4494
dc.identifier.issueNo2
dc.identifier.paperNo56
dc.identifier.urihttps://doi.org/10.3390/jmmp10020056
dc.identifier.urihttps://dspace.lib.cranfield.ac.uk/handle/1826/24955
dc.identifier.volumeNo10
dc.languageEnglish
dc.language.isoen
dc.publisherMDPIen_UK
dc.publisher.urihttps://www.mdpi.com/2504-4494/10/2/56
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject4014 Manufacturing Engineeringen_UK
dc.subject40 Engineeringen_UK
dc.subjectBioengineeringen_UK
dc.subjectBiomedical Imagingen_UK
dc.subjectGeneric health relevanceen_UK
dc.subject4016 Materials engineeringen_UK
dc.subject4017 Mechanical engineeringen_UK
dc.subjectclinical scanningen_UK
dc.subjectimage-based biomechanicsen_UK
dc.subjectpatient-specific FEAen_UK
dc.subjectmultiscale modellingen_UK
dc.subjectadditive manufacturingen_UK
dc.subjectbiofidelic physical analoguesen_UK
dc.titleSpine motion segment analogues: 3D printing, multiscale modelling and testing to produce more biofidelic examplesen_UK
dc.typeArticle
dcterms.coverageEdinburgh, Scotland
dcterms.dateAccepted2026-02-04
dcterms.temporal.endDate03-JUL-2024
dcterms.temporal.startDate30-JUN-2024

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Spine_motion_segment_analogues-2026.pdf
Size:
2.44 MB
Format:
Adobe Portable Document Format
Description:
Published version

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Plain Text
Description: