CERESResearch Repository

Failure mode transitions in asymmetric laminated safety glass under concentrated loading: analytical and experimental study

dc.contributor.authorKamal Jalali, S.
dc.contributor.authorDu, Minghan
dc.contributor.authorVanderpuye, Cuba-Kae
dc.contributor.authorXu, Xintian
dc.contributor.authorXu, Yigeng
dc.contributor.authorZhao, Yifan
dc.contributor.authorLiu, Haibao
dc.date.accessioned2026-07-02T10:56:22Z
dc.date.available2026-07-02T10:56:22Z
dc.date.freetoread2026-07-02
dc.date.issued2026-06-26
dc.date.pubOnline2026-05-27
dc.description.abstractObjectives: This study investigates the mechanical response and failure characteristics of asymmetric laminated safety glass with varying thickness ratios while maintaining a constant total thickness of 6 mm and using an EVA interlayer. Methods: A hybrid methodology combining quasi-static concentrated loading experiments with analytical modelling based on Classical Laminate Theory and Hertzian contact mechanics was employed. Beyond measuring peak loads and displacements, a semi-empirical system identification approach was developed to quantify the interlayer bonding efficiency (Γ) and effective bending stiffness. Fracture patterns were analysed using digital image processing to correlate stored elastic strain energy with post-failure crack density. Results: The results reveal a clear transition in failure behaviour depending on the outer glass layer thickness. Specimens with a thicker outer layer exhibited a global flexural failure mode, where the ultimate load scaled approximately linearly with laminate bending stiffness. In contrast, specimens with a thin outer layer under the applied load transitioned to a localised contact-dominated regime, where stress concentrations exceeded the nominal tensile strength of glass, causing premature failure below the global structural capacity. The specimen with the thickest outer layer achieved an ultimate failure load nearly twice that of the thinnest configuration and demonstrated approximately four times greater strain energy absorption before fracture. Conclusion: These findings show that increasing outer layer thickness enhances load-bearing capacity by shielding the interlayer and delaying localized fracture, although it also produces a denser crack network due to higher pre-failure energy release. The proposed physics-informed scaling laws provide a framework for optimizing asymmetric laminated glass in safety-critical applications.
dc.description.journalNameComposite Design and Manufacturing
dc.description.sponsorshipRoyal Society [RGS\R1\221405] and Innovate UK [AKT2I-114].
dc.identifier.citationKamal Jalali S, Du M, Vanderpuye C-K, et al., (2026) Failure mode transitions in asymmetric laminated safety glass under concentrated loading: analytical and experimental study. Composite Design and Manufacturing, Volume 2, Issue 2, June 2026, Article number wqag016en_UK
dc.identifier.eissn2977-7305
dc.identifier.elementsID871207
dc.identifier.issn2977-7305
dc.identifier.issueNo2
dc.identifier.paperNowqag016
dc.identifier.urihttps://doi.org/10.1093/cdm/wqag016
dc.identifier.urihttps://dspace.lib.cranfield.ac.uk/handle/1826/25387
dc.identifier.volumeNo2
dc.languageEnglish
dc.language.isoen
dc.publisherOxford University Press (OUP)en_UK
dc.publisher.urihttps://academic.oup.com/cdm/article/2/2/wqag016/8696436
dc.rightsAttribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject40 Engineeringen_UK
dc.subject4016 Materials Engineeringen_UK
dc.subject4001 Aerospace Engineeringen_UK
dc.subject7 Affordable and Clean Energyen_UK
dc.subjectlaminated safety glassen_UK
dc.subjectstructural integrityen_UK
dc.subjectfracture mechanicsen_UK
dc.subjectasymmetric layupen_UK
dc.subjectfailure mode transitionen_UK
dc.subjectstress shieldingen_UK
dc.titleFailure mode transitions in asymmetric laminated safety glass under concentrated loading: analytical and experimental studyen_UK
dc.typeArticle
dcterms.dateAccepted2026-05-12

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Failure_Mode_Transitions-2026.pdf
Size:
2.4 MB
Format:
Adobe Portable Document Format
Description:
Published version

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Plain Text
Description: