Fluorescence enabled direct visual observation for diagnosis of ultrafiltration membrane fouling by bi-disperse submicron particle suspensions

dc.contributor.authorAutin, Olivier
dc.contributor.authorSakar, H
dc.contributor.authorMcAdam, Ewan J.
dc.date.accessioned2018-05-25T14:19:08Z
dc.date.available2018-05-25T14:19:08Z
dc.date.issued2018-04-24
dc.description.abstractWhilst direct observation (DO) methodologies can describe back‐transport of supra‐micron particles, present technologies are unable to discriminate submicron particles, which are primarily responsible for membrane fouling. In this study, we therefore introduce a fluorescence enabled direct visual observation (RLF‐DVO) methodology to permit visual characterisation of submicron particle transport during cross‐flow filtration. Particle discrimination was achievable for particle diameters exceeding 0.25 µm; however, this was dependent upon particle concentration and the cross‐flow velocity employed. Nevertheless, this is considerably below the detection limit of current techniques (around 3 µm). During filtration of a binary dispersion comprised of submicron particles, deposition was observed before a change in transmembrane pressure was detected, which underpins the important role of DO for fouling diagnosis. Based on observations made during this study, recommendations are proposed that will further improve resolution. Importantly, this study demonstrates RLF‐DVO can provide real‐time description of submicron particle transport during cross‐flow filtration.en_UK
dc.identifier.citationAutin O, Sakar H, McAdam EJ, Fluorescence enabled direct visual observation for diagnosis of ultrafiltration membrane fouling by bidisperse sub-micron particle suspensions, Water and Environment Journal, Volume 32, Issue 4, pp. 519-526en_UK
dc.identifier.issn1747-6585
dc.identifier.urihttp://dx.doi.org/10.1111/wej.12349
dc.identifier.urihttp://dspace.lib.cranfield.ac.uk/handle/1826/13221
dc.language.isoenen_UK
dc.publisherWileyen_UK
dc.rightsAttribution-NonCommercial 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/*
dc.subjectBinaryen_UK
dc.subjectDirect observationen_UK
dc.subjectFluorescenceen_UK
dc.subjectSubmicronen_UK
dc.titleFluorescence enabled direct visual observation for diagnosis of ultrafiltration membrane fouling by bi-disperse submicron particle suspensionsen_UK
dc.typeArticleen_UK

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Fluorescence_enabled_direct_visual_observation-2018.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: